VF/VF 30/44

 

 

 

70 Nm

 

 

 

 

i

ηS

%

n2

min-1

Mn2

Nm

Pn1

kW

Rn1

N

Rn2

N

ηd

%

n2

min-1

Mn2

Nm

Pn1

kW

Rn1

N

Rn2

N

ηd

%

n1 = 1400 min-1

n1 = 900 min-1

 

 

VF/VF 30/44 _245

 245

29

5.7

 60

0.09

140

2500

40

 3.7

 70

 0.07

150

2500

38

VF/VF 30/44 _350

 350

27

4.0

 60

 0.07

  80

2500

36

 2.6

 70

 0.05

150

2500

38

VF/VF 30/44 _420

 420

25

3.3

 60

 0.06

2500

35

 2.1

 70

 0.04

2500

39

VF/VF 30/44 _560

 560

23

2.5

 60

 0.05

2500

31

 1.6

 70

 0.04

2500

29

VF/VF 30/44 _700

 700

21

2.0

 60

 0.04

2500

31

 1.3

 70

 0.03

2500

31

VF/VF 30/44 _840

 840

18

1.7

 60

 0.04

2500

26

 1.1

 70

 0.03

2500

26

VF/VF 30/44 _1120

 1120

16

1.3

 60

 0.03

2500

26

 0.80

 70

 0.02

2500

29

VF/VF 30/44 _1680

 1680

13

0.83

 60

 0.02

2500

26

 0.54

 70

 0.02

2500

20

VF/VF 30/44 _2100

 2100

12

0.67

 60

 0.02

2500

21

 0.43

 70

 0.02

2500

16

 

(–) Contact our technical service department advising radial load data (rotation direction, load angle, offset)

 


 

VF/VF 30/49

 

 

 

100 Nm

 

 

 

 

i

ηS

%

n2

min-1

Mn2

Nm

Pn1

kW

Rn1

N

Rn2

N

ηd

%

n2

min-1

Mn2

Nm

Pn1

kW

Rn1

N

Rn2

N

ηd

%

n1 = 1400 min-1

n1 = 900 min-1

 

 

VF/VF 30/49_240

 240

32

5.8

95

0.13

  80

3450

45

3.8

 100

 0.09

150

3450

44

VF/VF 30/49_315

 315

24

4.4

95

0.11

140

3450

40

2.9

 100

 0.07

150

3450

43

VF/VF 30/49_420

 420

24

3.3

95

0.08

3450

41

2.1

 100

 0.06

3450

37

VF/VF 30/49_540

 540

22

2.6

95

0.07

3450

37

1.7

 100

 0.05

3450

35

VF/VF 30/49_720

 720

20

1.9

95

0.05

3450

39

1.3

 100

 0.04

3450

33

VF/VF 30/49_900

 900

18

1.6

95

0.05

3450

31

1.0

 100

 0.04

3450

26

VF/VF 30/49_1120

 1120

15

1.3

95

0.04

3450

31

0.80

 100

 0.03

3450

28

VF/VF 30/49_1440

 1440

14

0.97

95

0.04

3450

24

0.63

 100

 0.03

3450

22

VF/VF 30/49_2160

 2160

11

0.65

 95

0.03

3450

21

0.42

 100

 0.02

3450

22

VF/VF 30/49_2700

 2700

10

0.52

95

0.03

3450

17

0.33

 100

 0.02

3450

17

 

(–) Contact our technical service department advising radial load data (rotation direction, load angle, offset)

 


 

 

(–) Contact our technical service department advising radial load data (rotation direction, load angle, offset)

 

(–) Contact our technical service department advising radial load data (rotation direction, load angle, offset)

 

(–) Contact our technical service department advising radial load data (rotation direction, load angle, offset)

 

(–) Contact our technical service department advising radial load data (rotation direction, load angle, offset)

 

(–) Contact our technical service department advising radial load data (rotation direction, load angle, offset)

 

(–) Contact our technical service department advising radial load data (rotation direction, load angle, offset)


 

(–) Contact our technical service department advising radial load data (rotation direction, load angle, offset)

 

VF/VF 130/210

 

 

 

 

 

6500 Nm

 

 

 

 

 

 

i

ηS

%

n2

min-1

Mn2

Nm

Pn1

kW

Rn1

N

Rn2

N

ηd

%

n2

min-1

Mn2

Nm

Pn1

kW

Rn1

N

Rn2

N

ηd

%

n1 = 1400 min-1

n1 = 900 min-1

 

 

 

VF/VF 130/210_280

 280

30

 5.0

 6300

 6.3

1500

34500

52

 3.2

 6500

 4.4

1500

34500

50

VF/VF 130/210_400

 400

28

 3.5

 6300

 4.6

1500

34500

50

 2.3

 6500

 3.2

1500

34500

48

VF/VF 130/210_600

 600

26

 2.3

 6300

 3.6

1500

34500

43

 1.5

 6500

 2.4

1500

34500

43

VF/VF 130/210_800

 800

25

 1.8

 6300

 2.8

1500

34500

41

 1.1

 6500

 2.0

1500

34500

38

VF/VF 130/210_920

 920

24

 1.5

 6300

 2.7

1500

34500

37

 1.0

 6500

 1.9

1500

34500

35

VF/VF 130/210_1200

 1200

21

 1.2

 6300

 2.2

34500

35

 0.75

 6500

 1.5

34500

34

VF/VF 130/210_1600

 1600

18

 0.88

 6300

 1.8

34500

32

 0.56

 6500

 1.2

34500

32

VF/VF 130/210_1840

 1840

19

 0.76

 6300

 1.7

34500

30

 0.49

 6500

 1.2

490

34500

28

VF/VF 130/210_2560

 2560

16

 0.55

 6300

 1.5

1220

34500

24

 0.35

 6500

 1.0

1500

34500

24

VF/VF 130/210_3200

 3200

15

 0.44

  6300

  1.3

1500

34500

22

 0.28

 6500

  0.96

1500

34500

20

 

(–) Contact our technical service department advising radial load data (rotation direction, load angle, offset)

 


 

VF/VF 130/250

 

 

 

9200 Nm

 

 

 

 

i

ηS

%

n2

min-1

Mn2

Nm

Pn1

kW

Rn1

N

Rn2

N

ηd

%

n2

min-1

Mn2

Nm

Pn1

kW

Rn1

N

Rn2

N

ηd

%

n1 = 1400 min-1

n1 = 900 min-1

 

 

VF/VF 130/250_280

 280

29

 5.0

 9000

 8.9

1500

52000

53

 3.2

 9200

 6.1

1500

52000

51

VF/VF 130/250_400

 400

27

 3.5

 9000

 6.7

1500

52000

49

 2.3

 9200

 4.6

1500

52000

47

VF/VF 130/250_600

 600

26

 2.3

 9000

 5.0

1500

52000

44

 1.5

 9200

 3.4

1500

52000

43

VF/VF 130/250_800

 800

24

 1.8

 9000

 3.9

1500

52000

42

 1.1

 9200

 2.7

1500

52000

40

VF/VF 130/250_920

 920

23

 1.5

 9000

 3.9

1500

52000

37

 0.98

 9200

 2.7

1500

52000

35

VF/VF 130/250_1200

 1200

20

 1.2

 9000

 3.1

52000

35

 0.75

 9200

 2.2

52000

33

VF/VF 130/250_1600

 1600

18

 0.88

 9000

 2.6

52000

32

 0.56

 9200

 1.8

52000

30

VF/VF 130/250_1840

 1840

18

 0.76

 9000

 2.3

52000

31

 0.49

 9200

 1.6

 490

52000

29

VF/VF 130/250_2560

 2560

16

 0.55

 9000

 2.1

1500

52000

25

 0.35

 9200

 1.5

1500

52000

23

VF/VF 130/250_3200

 3200

14

 0.44

 9000

 2.0

1500

52000

21

 0.28

 9200

 1.4

1500

52000

19

 

(–) Contact our technical service department advising radial load data (rotation direction, load angle, offset)