The C Series is designed for the requirements of standard tasks in the industrial environment. These series achieve first-rate reliability, efficiency, robustness, and a wide output torque range. The Read more...
The C Series is designed for the requirements of standard tasks in the industrial environment. These series achieve first-rate reliability, efficiency, robustness, and a wide output torque range. The extremely wide range of gear ratios, achieved through 2-, 3- or 4-stage versions, allows the customer to adapt the C Series to every application and to find the perfect match for output speed requirements. The C Series can be completed with a wide range of electric motors entirely manufactured by Bonfiglioli. Asynchronous motors both IEC and compact (BN-BE-BX/M-ME-MX), servomotors (BMD) and reluctance motors (BSR) can be coupled with the C Series. Read less...
Key benefits - Minimized mounting space |
|
Main options | Main option Surface protection up to C5 Double oil seals Fluor Elastomer Seals Reduced Backlash |
Torque range | 45 ... 12.000 |
Torque range (IU) | 398 … 106,208 |
Gear ratios | 2,6 ... 1.481 |
Certifications | CUS,CCC,CEL,NBR,EECA,BIS |
Transmissible mechanical power | 0.09 ... 213 kW |
Output | Feet or flange mounting, B14 flange Metric or inch series solid output shaft |
Motors Input with solid shaft |
|
Motors options Thermistors and thermostat sensors |
Product Catalogue –Industrial Gearmotors-C-A-F-NEMA
Selection Of Gearboxes- Industrial Gearmotors-C-A-F-S-VF-W
Designation | Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C 36 2 11.7 BX 90LA 4
Please continue to proceed with product configuration
Available Variants
|
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
IN-LINE | 4740.0 | 6.5 | 3.0 | IE3 | 11.7 | IEC | 1.5 | 111.0 | 123.0 | 479.44 | 3.4 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
IN-LINE | 4590.0 | 6.5 | 3.0 | IE3 | 13.3 | IEC | 2.2 | 186.0 | 107.0 | 535.44 | 2.0 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
IN-LINE | 4260.0 | 6.5 | 3.0 | IE3 | 13.3 | IEC | 3.0 | 253.0 | 108.0 | 584.94 | 1.5 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
IN-LINE | 3840.0 | 6.5 | 3.0 | IE3 | 13.3 | IEC | 4.0 | 342.0 | 108.0 | 664.44 | 1.1 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
IN-LINE | 3053.0 | 8.1 | 3.0 | IE3 | 13.3 | IEC | 5.5 | 380.0 | 132.0 | 809.44 | 0.9 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
IN-LINE | 4890.0 | 6.5 | 3.0 | IE3 | 13.3 | IEC | 1.5 | 127.0 | 107.0 | 479.44 | 3.0 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
IN-LINE | 4710.0 | 6.5 | 3.0 | IE3 | 14.8 | IEC | 2.2 | 206.0 | 97.0 | 535.44 | 1.8 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
IN-LINE | 4340.0 | 6.5 | 3.0 | IE3 | 14.8 | IEC | 3.0 | 280.0 | 98.0 | 584.94 | 1.4 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
IN-LINE | 3880.0 | 6.5 | 3.0 | IE3 | 14.8 | IEC | 4.0 | 378.0 | 98.0 | 664.44 | 1.0 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
IN-LINE | 5030.0 | 6.5 | 3.0 | IE3 | 14.8 | IEC | 1.5 | 140.0 | 97.0 | 479.44 | 2.7 |