The S Series design makes this gearmotor particularly effective for pump, fan and blower applications. To meet the needs of customers in these sectors, the S Series is also available in the foot or fl Read more...
The S Series design makes this gearmotor particularly effective for pump, fan and blower applications. To meet the needs of customers in these sectors, the S Series is also available in the foot or flange versions and can be completed with a wide range of electric motors entirely manufactured by Bonfiglioli. Asynchronous motors both IEC and compact (BN-BE-BX/M-ME-MX) and reluctance motors (BSR) can be coupled with the S Series. With the breadth of its portfolio, Bonfiglioli provides customers with an outstanding balance of efficiency, dynamics and cost effectiveness. Read less...
Key benefits - Cost effective solution |
|
Main options | Gearbox supplied with oil [Size 50] Surface protection up to C5 Fluor Elastomer oil seals |
Torque range | 21 ... 200 |
Torque range (IU) | 185 … 1,770 |
Gear ratios | 1,4 ... 13,1 |
Certifications | CUS,CCC |
Transmissible mechanical power | 0.09 ... 11.6 kW |
Output | Feet mounting Flange mounting |
Motors Input with solid shaft |
|
Motors options Thermistors and thermostat sensors |
Selection Of Gearboxes- Industrial Gearmotors-C-A-F-S-VF-W
Designation | Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
S 50 1 6.1 BN 100LA 4
Please continue to proceed with product configuration
Available Variants
|
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
PARALLEL | 4060.0 | 21.0 | 8.0 | IE1 | 6.1 | IEC | 2.2 | 88.4 | 233.0 | 583.78 | 1.5 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
PARALLEL | 3910.0 | 21.0 | 8.0 | IE1 | 6.1 | IEC | 3.0 | 120.6 | 233.0 | 611.78 | 1.1 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
PARALLEL | 3160.0 | 18.9 | 8.0 | IE1 | 6.1 | IEC | 4.0 | 79.0 | 474.0 | 774.78 | 1.3 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
PARALLEL | 4520.0 | 0.0 | 9.0 | IE1 | 6.1 | IEC | 2.2 | 134.1 | 154.0 | 651.78 | 1.1 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
PARALLEL | 3020.0 | 18.9 | 8.0 | IE1 | 6.1 | IEC | 5.5 | 107.9 | 477.0 | 898.28 | 0.9 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
PARALLEL | 3340.0 | 18.9 | 9.0 | IE1 | 6.1 | IEC | 2.2 | 44.4 | 464.0 | 651.78 | 2.3 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
PARALLEL | 4840.0 | 0.0 | 9.0 | IE1 | 6.1 | IEC | 1.1 | 67.8 | 152.0 | 540.78 | 2.2 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
PARALLEL | 4270.0 | 21.0 | 8.0 | IE1 | 6.1 | IEC | 1.1 | 44.5 | 231.0 | 507.28 | 2.9 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
PARALLEL | 4940.0 | 0.0 | 8.0 | IE1 | 6.1 | IEC | 0.75 | 46.2 | 152.0 | 523.78 | 3.2 |
Please continue to proceed with product configuration
Available Variants
Cant find what youre looking for? Go to the configurator
Layout | Rn2 [N] | PT [kW] | Lead Time | Motor Efficiency (NEMA) | i | Motor Interface Type | Pn1 [kW] | Mn2 [Nm] | n2 [rpm] | $ | Service Factor |
---|---|---|---|---|---|---|---|---|---|---|---|
PARALLEL | 3440.0 | 18.9 | 3.0 | IE1 | 7.4 | IEC | 3.0 | 72.6 | 386.0 | 687.78 | 1.4 |